ROCKWOOL- LRB MATTRESS

Industry Industry / OEM- Steam pipe, Boiler, Furnace, Tank, Other hot application
Form Low Resin Bonded Mattress
Density 70- 160 kg/m3
Thickness 25- 100mm
Thermal Conductivity 0.059 at 200° C mean temperature
Shot content
< 25%
Non-combustibility Non-combustible / Incombustible- Confirming to BS 476 Part 4, IS 8183
Facings Unfaced, FSK

ROCKWOOL- RESIN BONDED SLAB

Industry Building, OEM
Form Resin Bonded Slab
Density 40 to 180 kg/m3
Thickness 25 to 150 mm
Thermal Conductivity 0.059 to 0.074 at 200° C mean temperature
Shot Content < 25%
Non-combustibility Non-combustible / Incombustible
Facings FSK, Alu Glass, Black Glass Tissue, and Black Glass Fabric

CERAMIC WOOL

Industry Crude Oil, Reformer & Pyrolysis heater linings, Tube seals, Gaskets & Expansion joints, Heat treatment furnaces
Form Blankets
Density 64-160 kg/m3
Thickness 6mm- 50mm
Thermal Conductivity 0.1032 at 25ºC W/mK
Service Temperature Upto 1425
Non-combustibility Non-combustible / Incombustible, Reaction to Fire 'A1'
Facings Unfaced, Foil-Faced, Vermiculite-Faced, and Needled or Reinforced

POLYURETHANE

Industry Insulation of Pipes, insulation of reducers, insulation of storage tanks, and insulation of boilers.
Form Slabs
Density 30 and 70 kg/m
Thickness 20 to 200mm
Thermal Conductivity 0.025 to 0.035 W/mK at 20°C
Service Temperature
Up to 110°C
Closed Cell Content 85
Compressive Strength 115
Facings Kraft Paper / FSK

POLYURETHANE

Industry HVAC systems, industrial processes, and cold storage
Form PUF Sections (CNC Cut)
Density 36 -50 kg/m3
Thickness 25mm and above
Thermal Conductivity 0.020 to 0.030 W/m·K at 25°C
Service Temperature
-180°C to +120°C
Non-combustibility Fire Resistant
Facings Ceramic fiber blanket

POLYISOCYANURATE

Industry Under-deck Roof, Walls, and Flooring of Cold Areas
Form PIC Sections (CNC Cut)
Density 36 -50 kg/m3
Thickness 25mm and above
Thermal Conductivity 0.016 to 0.028 W/mK
Service Temperature -200°C to +140°C
Non-combustibility Non-combustible / Incombustible
Facings Bare, Bituminised Paper, Kraft Paper, Aluminum Foil Paper

POLYISOCYANURATE

Industry Insulation of Pipes, insulation of reducers, insulation of storage tanks, and insulation of boilers.
Form Slabs
Density 45 and 70 kg/m³
Thickness 0 to 200mm
Thermal Conductivity 0.022 to 0.027 W/mK at 10°C
Service Temperature Up to 140°C
Closed Cell Content 95
Compressive Strength 115
Facings Kraft Paper / FSK

NITRILE FOAM

Industry Insulation to prevent condensation and reduce energy loss on HVAC ducts, pipes, tanks & equipment.
Form Sheets
Density 40- 60 kg/m3
Confirming to ASTM-D-1065
Thickness 1 mm to 32 mm
Thermal Conductivity ≤0.035 W/m°K at 10°C
≤0.036 W/m°K at 20°C
Service Temperature
-40°C to 105°C
Non-combustibility Class 1 or Class 0 for fire resistance
Facings Unfaced / Alupet / Glass cloth

NITRILE FOAM

Industry Insulation to prevent condensation and reduce energy loss on HVAC ducts, pipes, tanks & equipment.
Form Tubing
Density 40- 60 kg/m3
Confirming to ASTM-D-1065
Thickness 6 mm to 32 mm
Thermal Conductivity ≤0.035 W/m°K at 10°C
≤0.036 W/m°K at 20°C
Service Temperature -40°C to 105°C
Non-combustibility Class 1 or Class 0 for fire resistance
Facings Unfaced / Alupet / Glass cloth

CELLULAR GLASS

Industry Cold and cryogenic tank bases, • Hot and high temperature tank bases
Form Slab
Density 120 kg/m3
Confirming to EN 1602
Thickness 25mm and above
Thermal Conductivity 0.022 to 0.080 W/(m·K) at -160°C
Service Temperature
-265 to +430 °C
Confirming to EN 14706
Non-combustibility Euroclass A1, Non-combustible
Confirming to EN 13501-1
Compressive Strength CS > 800 kPa
Confirming to EN 826 Annexe A

PERLITE

Industry Insulation of Pipes, insulation of reducers, insulation of storage tanks, and insulation of boilers.
Form Slab
Density 192-224 Kg/ Cu.M
Confirmed by ASTM C302/303
Thickness 25 to 100mm
Thermal Conductivity 0.062 W/mK @25°C
Service Temperature
Upto 650° C
Compressive Strength 40 KN/ Sq.M
Confirmed by ASTM C165
Surface burning characteristics
Flame Spread-0 Smoke Developed-5
Confirming to ASTM E84

PERLITE

Industry Insulation of Pipes, insulation of reducers, insulation of storage tanks, and insulation of boilers.
Form Sections
Density 192-224 Kg/ Cu.M
Confirmed by ASTM C302/303
Thickness 25 to 100mm
Thermal Conductivity 0.062 W/mK @25°C
Service Temperature Upto 650° C
Compressive Strength 40 KN/ Sq.M
Confirmed by ASTM C165
Surface burning characteristics
Flame Spread-0 Smoke Developed-5
Confirming to ASTM E84

XLPE FOAM

Industry Thermal insulation for pipes, ducts, vessels (including elbows, fittings, flanges, etc)
Form Sheets
Density 30 KG/m³ (Foam core only) (+/-5)
Confirming to ASTM D3575
Thickness 3 to 25mm
Thermal Conductivity 0.031W/mK at 0°C
0.034W/mK at 23°C
Confirming to ASTM C 518
Service Temperature
-20°C to 110°C
Confirming to CIPET
Water vapour diffusion resistance factor ≥ 17000 (Foil Facing)
Confirming to BS EN 12086

XLPE FOAM

Industry Thermal insulation for pipes, ducts, vessels (including elbows, fittings, flanges, etc)
Form Tubings
Density 30 KG/m³ (Foam core only) (+/-5)
Confirming to ASTM D3575
Thickness 6, 10, 12, 15, 20, 22, 25, 28, 32, 35, 42, 48, 54, 60mm
Thermal Conductivity 0.031W/mK at 0°C
0.034W/mK at 23°C
Confirming to ASTM C 518
Service Temperature
-20°C to 110°C
Confirming to CIPET
Water vapour diffusion resistance factor ≥ 17000 (Foil Facing)
Confirming to BS EN 12086